mrimprank.Rd
MRI MPRAGE Ranking
data(mrimprank)
A data frame with 9412 rows and 15 variables
A dataset with variables as follows:
RID N Participant roster ID
SITEID N Site ID
VISCODE T Visit code
USERDATE S Date record created
RECNO N
EXAMDATE D Examination Date
FLDSTRENG N Field Strength
COILTYPE T Coil Type
SCAN N Scan
LONISID N LONI Study ID
LONIUID T LONI Unique Series ID
RANK N MPRAGE Rankings: The MPRAGE rankings are done in a qualitative manner.A scan with a 1 ranking is considered a high quality scan. A 2 ranking is considered a medium quality scan. 3 ranking is a low quality scan.3 is the lowest ranking a scan can receive and still be considered a passing scan. Anything below 3 would be a failure for quality. Choosing MPRAGES: For scans ranked 2 and 3 the scan ranked 2 (whatever is the lower ranking of the two) should always be the "preferred/chosen"MPRAGE. If the rankings are tied in ranking the QC-er would chose the"sharper of the two". If the two scans are identical the first MPRAGE was always chosen. The preferred scan is indicated by the LONIUID field in the MRIMPPRO table.
USERDATE2 S Date record last updated